EV charging with EMHASS as planner and evcc as executor#

Goal#

Let EMHASS decide when and how much to charge an EV, as one deferrable load in the whole-home optimization, and let evcc carry that plan out on the vehicle. EMHASS does the time-shifting: which slots to charge in, against the tariff and the PV forecast. evcc is the vehicle-aware executor: it talks to the car properly, reads live SOC, holds the charge current inside the charger’s safe limits, speaks the vehicle API or OCPP, and keeps the car awake. EMHASS stays the planning brain and evcc is the actuator. The two never fight over the plan.

This is the opposite coupling to evcc-io/evcc#29815, which proposes evcc calling EMHASS as its optimizer backend. Here evcc never optimizes the EV. It only carries out EMHASS’s per-timestep decision. The two recipes can coexist later. This one works today with released evcc and EMHASS.

Prerequisites#

  • EMHASS version: any current release (Steps 1-4). Step 5 (def_current_power) needs a release after v0.17.7: it is merged on master via PR #982 / #605 but not yet in a tagged release.

  • Optimization mode: naive-mpc-optim.

  • An evcc instance bound to the vehicle (a vehicle-API or OCPP charger). evcc holds its own vehicle credentials and reads SOC directly.

  • evcc must NOT control the house battery. Exclude the battery from evcc’s meters. EMHASS owns battery dispatch.

  • Transport tested against: Home Assistant Core 2024.x, evcc 0.309 (default API port 7070). EMHASS REST is called via a HA rest_command.

Step 1: Configure the EV as a deferrable load#

The EV is a windowed deferrable load: a fixed energy amount to deliver before a deadline, at up to the charger’s nominal power. This is the same base setup as the EV study case, so start there for the full config. The slot looks like:

number_of_deferrable_loads: 3
nominal_power_of_deferrable_loads:
  - 3000          # water heater
  - 750           # pool pump
  - 11000         # EV charger nominal power (e.g. 11 kW = 3-phase 16 A)
operating_hours_of_each_deferrable_load: [5, 8, 0]   # EV hours overridden at runtime
start_timesteps_of_each_deferrable_load: [0, 0, 0]
end_timesteps_of_each_deferrable_load:   [48, 48, 0] # EV end overridden at runtime

Expected: EMHASS restarts cleanly and naive-mpc-optim returns a plan with a third deferrable.

Step 2: Feed live EV state into each MPC call#

Each MPC call computes the EV’s remaining energy and deadline fresh. evcc reports live SOC, which the evcc Home Assistant integration exposes as a sensor, so a HA rest_command can read it and translate to EMHASS’s def_total_hours (fractional hours are honoured, see Caveats) and end_timesteps. The deadline is computed in the template, not read from evcc:

rest_command:
  emhass_mpc:
    url: http://localhost:5000/action/naive-mpc-optim
    method: POST
    timeout: 120
    headers: {content-type: application/json}
    payload: >
      {%- set charger_kw = 11.0 -%}
      {%- set timestep_min = 30 -%}
      {%- set horizon = 48 -%}                         {# horizon_steps; the per-load arrays below are length = your deferrable count (3 here) #}
      {%- set ev_remaining_kwh = states('sensor.evcc_ev_remaining_kwh') | float(0) -%}
      {%- set ev_hours = (ev_remaining_kwh / charger_kw) | round(2) -%}
      {%- set deadline = today_at("05:00") if now() < today_at("05:00") else today_at("05:00") + timedelta(days=1) -%}
      {%- set end_step = ((deadline - now()).total_seconds() / 60 / timestep_min) | int -%}
      {
        "prediction_horizon": {{ horizon }},
        "soc_init": {{ states('sensor.battery_soc') | float(0) / 100 }},
        "def_total_hours": [ {{ states('sensor.wh_remaining_hours') | float(0) }}, {{ states('sensor.pool_remaining_hours') | float(0) }}, {{ ev_hours }} ],
        "end_timesteps_of_each_deferrable_load": [ {{ horizon }}, {{ horizon }}, {{ end_step }} ]
      }

The sensor.* names here are placeholders. Replace them with the entities your own setup publishes; the evcc_* names are not guaranteed entity ids from the evcc integration. Every read uses | float(0) on purpose, so an unavailable sensor degrades to 0 rather than injecting the literal string unknown and producing invalid JSON.

Expected: the MPC response’s P_deferrable2 (the EV) is non-zero only inside the charging window.

Step 3: Execute the plan with evcc, not a bare on/off switch#

EMHASS schedules the deferrable as on-at-nominal-or-off per timestep, and it has already done the optimization: which slots to charge in, given the tariff and the PV forecast. Step 3 just enforces that decision on the car. The reason to use evcc instead of a bare on-off switch is not extra optimization, it is that evcc talks to the vehicle properly: it reads live SOC, holds the current inside the charger’s safe range, speaks the vehicle API or OCPP, and knows when the car is asleep. A relay does none of that.

Define two rest_commands that set the evcc loadpoint mode. evcc listens on port 7070 by default, and its loadpoint paths are 1-based, so the first loadpoint is /loadpoints/1 even though /api/state reports it as index 0:

rest_command:
  evcc_mode_now:
    url: http://EVCC_HOST:7070/api/loadpoints/1/mode/now
    method: post
  evcc_mode_off:
    url: http://EVCC_HOST:7070/api/loadpoints/1/mode/off
    method: post

Then map EMHASS’s per-timestep decision to a mode rather than a switch:

automation:
  - alias: EV follow EMHASS plan (via evcc)
    trigger: [{platform: state, entity_id: sensor.p_deferrable2}]
    action:
      - choose:
          - conditions: [{condition: numeric_state, entity_id: sensor.p_deferrable2, above: 100}]
            sequence:
              - service: rest_command.evcc_mode_now
          - default:
              - service: rest_command.evcc_mode_off

sensor.p_deferrable2 is the EV because the EV is the third deferrable in the Step 1 load order (the index is 0-based, so the third load is 2). If you change the deferrable order, adjust the sensor name and index to match.

now charges at the charger’s configured rate during the slots EMHASS picked. EMHASS, not evcc, decides when those slots are, so the tariff and PV optimization still happens, it just happens in the planner. If you would rather evcc follow PV surplus within a slot, use the pv or minpv variant in Step 4 and accept the trade-off it carries.

Expected: when the plan shows EV power, evcc starts or holds the charge; when the plan drops to zero, evcc stops. evcc’s live SOC feeds the next MPC call (Step 2), closing the loop. A sleeping car will not respond to now until it is woken (see Caveats).

Step 4: Overnight minimum-SOC-by-deadline (the “floor”)#

The common real requirement is “have the car at X% by 05:00, cheapest way possible, never during the evening peak.” Express it entirely through Steps 1-2: set the EV’s required energy to (target_soc - current_soc) * battery_kWh and end_timesteps to the 05:00 deadline. EMHASS then places the charge in the cheapest in-window slots and leaves the peak alone, and Step 3 enforces it with now during those slots.

If instead you want “PV surplus first, grid only as a last resort,” that is an evcc-side choice and a different trade-off. Run evcc in pv or minpv mode for the window in place of the Step 3 now mapping, and keep a house-battery reserve so EMHASS doesn’t plan the battery flat. The cost is that pv/minpv throttles to available surplus, so evcc can deliver less than EMHASS planned and the deadline target is no longer guaranteed. Use now (Step 3) when hitting the target matters more than maximising self-supply, and pv/minpv when it is the other way round. Don’t run both mappings at once, they fight.

Expected: with the Step 3 now mapping the car reaches the target by the deadline using the cheapest in-window slots; with the pv/minpv variant it charges from surplus and may stop short on a low-sun day.

Step 5: Handle a manually-started or mid-window charge#

If the driver plugs in and starts charging by hand mid-window, the house load sensor (sensor_power_load_no_var_loads) excludes the charger, so P_load[0] handed to EMHASS is too low and the optimizer may plan to switch off the load the driver just switched on. This is the study case “Mid-session state is not forced” limit.

Pass the charger’s actual current power in watts as def_current_power (a runtime-only per-load list, in the same order as nominal_power_of_deferrable_loads). EMHASS pins the first timestep to that power, forces the load ON at t=0, and suppresses the phantom startup penalty:

{# add to the Step-2 payload, from evcc's live charge power #}
"def_current_power": [ 0, 0, {{ states('sensor.evcc_ev_charge_power_w') | float(0) }} ]

Expected: when the car is charging at, say, 6.8 kW, the plan’s first EV timestep is pinned to 6.8 kW and the optimizer schedules around it instead of stopping it.

Caveats#

  • Coupling direction. This is evcc-as-executor under EMHASS, not the evcc-as-frontend proposal in #29815. Don’t wire both.

  • No within-slot PV modulation by default. EMHASS plans on-or-off-at-nominal per timestep (the study case power-modulation limit) and does the time-shifting; the Step 3 now mapping enforces it at the charger’s configured rate. If you want evcc to follow PV surplus inside a slot, use the pv/minpv variant in Step 4 and accept it may under-deliver versus the plan.

  • Deadline maths assumes no DST. The Step 2 timedelta(days=1) is exactly 24 hours, so on a timezone that observes daylight saving the 05:00 deadline can land an hour off on the switch days. Adjust the template if that applies to you.

  • A missed deadline rolls into the next day. Once 05:00 passes, the Step 2 template sets the deadline to the next 05:00, so if the car did not reach target overnight (it under-delivered on a low-sun pv/minpv night, or it was unplugged) the leftover energy carries a next-day deadline. EMHASS then schedules it in the cheapest slots before then, which can be the next day’s midday PV. That is the cheapest outcome by design, but if you need the charge kept to overnight, bound the window: set the EV deferrable’s start_timesteps/end_timesteps to the overnight slots, or gate the Step 3 automation on time of day, so a missed night does not become a daytime charge.

  • def_current_power needs a release after v0.17.7. Before that, Step 5 doesn’t apply and a manual mid-window charge may be re-planned off.

  • Keep evcc off the house battery. Exclude the battery from evcc’s meters. EMHASS owns it.

  • Secure the control endpoints. These examples call EMHASS and evcc over plain HTTP on the LAN. evcc’s loadpoint API has no authentication of its own, and the EMHASS /action/* endpoints command real loads, so don’t expose either to the internet unprotected. Keep them on the local network, or put them behind a reverse proxy that adds TLS and auth.

  • Fail safe. An executor or transport failure should default to a safe state (a kill-switch plus a watchdog that stops commanding on stale data). See Good Practices.

  • Vehicle-API charging needs the car awake. evcc does not auto-wake (evcc#28652); wake the car before commanding.